The Solution 3000

The New Solution 3000 security system from Bosch brings the latest sophisticated global technology in security panels to your home or small business right here in Australia.  With double the number of zones compared with the previous Ultima range, unsurpassed flexibility, quality and features, you can rest easy with this system protecting your property and family.  With a variety of codepad options for flexibility, the LCD Alphanumeric codepad displays information in real text for ease of use, or manage your system from the Bosch Remote Security Control app on your phone.  Coming soon are the exciting touchpads which provide all the advantages of wireless control wherever you want it around the house!

The Solution 3000 supports up to 16 fully programmable zones.  Up to four keypads can be supported and the system can be split into two separate partitions in the situation of a home/granny flat or any other similar requirement.

Due to harsh Australian conditions, we recommend as a minimum the Quad detectors, which are included in this kit.  The Blue Line Gen2 Quad PIR Detector (ISC-BPQ2‑W12) uses two individual sensors that operate like two PIRs in one detector. Each sensor processes signals separately. Both must activate to generate an alarm signal. This improves false alarm immunity relative to a standard PIR, because false alarm sources such as noise spikes and small animals are ignored.

The package will include the following:

  • 3 wired Blue Line Quad Detectors
  • Includes indoor and outdoor sirens
  • Includes keypad
  • Includes power supply and battery
  • Includes resistors, phone leads, tamper switches and lots more.
  • Includes all cable and connectors
  • Includes ADSL Filter if required
  • Includes 5 X Security Stickers
  • Comes with manuals and cheat sheet
  • Fully configured with your codes and either domestic (your phone) or Back to Base dialling

Feel free to ask any questions by dropping us a line or calling 1300 004 226

(IC-BCH-F01U305341INS)

Configure your combo.



** Fully installed and configured to a single story property with normal roof space
** Complete with a 3 years part and labour warranty
** Sign up for a one year back to base service and receive a 10% discount on your installation price!!!
  • 16 Fully Programmable Zones
  • 41 Codes - 1 Installer, 20 User Codes, 20 RF Keyfobs
  • Up to 4 Keypads (1 Icon Keypad included in this package)
  • Partitionable to two separate areas
  • Stay/Away Arming Options
  • Selectable Reports Per User Code
  • Entry and Exit Warning
  • Automatic Arming
  • Remote Arming
  • 256 Event History Memory
  • LCD Icon, LCD Aphanumeric and Touchscreen support
  • 5 Programmable Outputs
  • Back to Base Reporting

Functions

User codes

Users can program up to 20 user codes and 20 radio user codes. Only the Master Code holder can add or change other system user codes.

Two areas

The control panel is partitioned into two areas. Operate both areas from one master codepad or from multiple separate area addressable codepads.

Remote programming

Users can program the zones remotely with CC816 Alarm Link (A‑Link) software on a PC with MS‑DOS and a modem. Users can run diagnostics, arm systems, and bypass zones with an off‑site computer. This reduces service visits to a site and provides quick customer service, saving time and money. Remote programming is useful for country locations where a control panel might be located hundreds of kilometers (miles) from an office.

Three arming modes

Users can arm the system using one of three modes:
AWAY Mode: Arms the entire system.
STAY Mode 1: Arms all zones except those programmed by the installer to be automatically isolated.
STAY Mode 2: Arms all zones except those programmed by the Master Code holder to be automatically isolated.

Remote arming

This feature allows the system to be armed from any remote location by telephone. For obvious security reasons, the system cannot be disarmed using this method. A touch-tone telephone is required to use this feature. For this feature to operate, it must be programmed at installation.

Day alarm

Day alarm monitors a group of zones when the system is disarmed. For example, the front door of a shop has a pressure mat or electronic beam that customers activate as they enter or exit. The codepad beeps each time the mat or beam activates.

Duress alarm

A codepad duress alarm can work as a silent hold-up alarm and is useful when the system reports to a monitoring station or pocket pager.

Codepad tamper alarm

Codepad tamper limits the number of times that someone can try to enter the wrong user code. When someone exceeds the limit, the system starts an alarm and sends an Access Denied Report to a security monitoring station.

Built-in telephone line fail monitor

The system registers a telephone line fault when the system detects that the telephone line has been disconnected from the control panel. The system can be programmed to sound if the telephone line is cut when the panel is armed.

Zone lockout

The first zone to send an alarm condition is locked and a siren runs for a specified time. All other zones that send alarm conditions are reset when the sirens reset, but continue to report if another alarm condition occurs. This prevents an intruder from setting off the alarms in all zones, waiting for the sirens to stop, and then entering the site.

Dynamic battery testing

The system automatically performs a battery test every 4 hours and also every time you arm the system. The system registers a low battery fault when the system detects a low capacity back-up battery.

Event memory recall

Events are stored in non-volatile memory. Event memory recall plays the last 40 system events, including all alarms, system arming, and system disarming. If the control panel is partitioned, Event Memory Recall plays the last 10 system events.

Programmable ring burst time

Telephone ring times might be longer or shorter depending on the technology in a system. Different timing can cause control panels to answer calls that should be answered by an answering machine, fax, or a person. Users can program the control panel for the correct ring burst time; adjusting the ring time by 5 ms up to a total of 75 ms, or by 80 ms up to a total of 1200 ms.

AC Fail and System Fault indicators

If a fault occurs, the FAULT or MAINS indicator flashes and the codepad beeps once every minute.

End-Of-Line (EOL) resistor value choice

Users can choose different EOL resistor values when programming the control panel. The selected value applies to all zones at once. Users can add the control panel into an existing system without changing the EOL resistors.

Telco arm/disarm sequence (call forwarding)

This feature is only available if the call-forward option is available from the telecommunications provider. It allows programming of the Call Forward –Immediate On sequence or Call Forward –No Answer sequence that will automatically operate when the system is armed in the AWAY Mode.

Call Forward Modes
Immediate On: Redirects all incoming calls to another number, including mobile phones, pagers, and answering services. The telephone called first does not ring.
No Answer: Redirects all incoming calls to another number when the telephone that was called first is not answered within 20 seconds. Outgoing calls can still be made from the first telephone.

The Solution 3000 has a wide variety of useful features such as:

  • The Solution 3000 has a wide variety of useful features such as:

  • 20 programmable user codes and 20 radio remote user codes
  • Two areas
  • DTMF telephone remote arming
  • Remote programming
  • Three arming modes
  • Day alarm, duress alarm, and codepad tamper alarm
  • Built-in telephone line fault monitor
  • Zone lockout
  • Dynamic battery testing
  • Event memory recall

Electrical

Current Draw

In alarm: 115 mA
In alarm with codepad: 105 mA
In standby: 65 mA

Power

Primary: 240 VAC, 18 VAC at 1.3 A from a TF008 Plug Pack
Secondary: 12 VDC, 6.5 Ah from a rechargeable sealed lead/acid battery

Environmental

Relative Humidity: 10% to 95% non-condensing
Temperature (Operating): 0°C to +45°C (+32°F to +113°F)

Mechanical

Dimensions (packed in carton): 306 mm x 262 mm x 84 mm (12.1 in. x 10.3 in. x 3.3 in.)
Weight: 2.5 kg (5.5 lb)


Warranty

All iCam Security products are covered by an extensive warranty and your product will be of the highest quality and deliver years of reliable service. All products conform to ISO 9001 standards (International Organisation for Standardisation), ensuring a set of International Quality Management standards and principles are followed.

In addition to any warranty by virtue of statute, all labout and products are covered by a three year warranty from date of invoice.

Sometimes in rare cases, an item will have a manufacturing defect or be damaged. In these rare cases, please phone us on 1300 004 226 or email enquiries@icamsecurity.com.au to make a claim. Our goal is to offer the fastest turnaround service if these cases happen.

We will do our best to see that the items you order are the correct ones, and although it is your responsibility to ensure that items you order are correctly specified for the intended use, we may exercise the discretion to replace an item that you purchased but incorrectly specified.

Be The First To Review This Product!


Help other iCam Security users shop smarter by writing reviews for products you have purchased.

Click here to write a product review


Others Also Bought...



More From This Category...